Help

ORALTOX® QUIZ


Please read each question and select the best answer. Select your answer by clicking the button next to it. After you have answered all of the questions click ‘Submit Answers’ and your test will automatically be scored.

1. The OralTox has the ability to test for up to how many drugs?
5 drugs
6 drugs
8 drugs
12 drugs

2. Advantages of oral fluid testing include?
Eliminate need for controlled collection sites
No need for same sex collectors
Resistant to adulteration
Less invasive means of drug testing
All of the above

3. Ten minutes prior to collection, it is important that the donor...
Use the restroom
Has no food, drink, gum, etc. in their mouth
Begin pooling oral fluid in mouth
Drink 8 ounces of water

4. How does the test administrator know that the specimen collection step is complete
2 minutes has passed
10 minutes has passed
The donor takes the swab out of his/her mouth
When color appears in the indicator window of the collection swab

5. Negative results may be read ___. Interpret remaining results as negative, presumptive positive or invalid at ___ minutes.
as soon as the control and test lines appear/10 minutes
at 3 minutes/5 minutes
at 10 minutes/10 minutes

6. Prior to testing, it is important that___?
The donor has no food, drink, gum, etc. in his/her mouth
Test device are at room temperature
The administrator verify that the device has not expired
All of the above

FOR QUESTIONS 7 & 8, PLEASE REFER TO THE FOLLOWING IMAGE
Click to Expand

7. According to the results shown in the image, this drug test panel indicates a negative result for___?
AMP
BZO
COC
MTD
COC, MET, OPI, PCP, THC

8. According to the results in the image above, this drug test panel indicates a presumptive positive for___?
AMP
COC, MET, OPI, PCP, THC
THC
OPI

9. Once the control line appears in the test region (C), any indication of a line (regardless of intensity) in the test region (T) should be considered a line and therefore a negative result.
TRUE
FALSE

10. After the specimen is collected and the test activation phase begins, it is important that the test device is positioned upright on a flat surface until it is time to interpret results.
TRUE
FALSE

11. Typically, donors will saturate the sponge within 2-4 minutes of collection. However, for some candidates it may be necessary for collection to exceed 4 minutes if they are experiencing dry mouth?
TRUE
FALSE

12. To speed up collection, instruct the donor to chew gently on the sponge.
TRUE
FALSE




© Premier Biotech LLC All Rights Reserved.